- Все продукты
- /
- Connectors, Interconnects
- /
- Terminals - Rectangular Connectors
| Изображение | Тип | Марка | Объяснение | Установленная цена | Количество | RoHS | Factory Lead Time | Contact Plating | Mount | Mounting Type | Package / Case | Contact Materials | Packaging | Published | Series | Pbfree Code | Part Status | Moisture Sensitivity Level (MSL) | Termination | ECCN Code | Color | HTS Code | Depth | Contact Finish | Wire Gauge | Body Plating | Wire/Cable Gauge | Terminal and Terminal Block Type | Insulation | Terminal Type | Stud/Tab Size | Terminal Style | Terminal Gender | Length | Length - Overall | Width - Outer Edges | Tab Thickness | Diameter - Barrel ID | Diameter - Barrel OD | Diameter - Ring ID | Radiation Hardening | RoHS Status |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Mfr. ТипLCD4-38AD-LAnlielectronics Тип | Panduit Corp |
Lug Terminal 2AWG 72.3mm 15.7mm Tin
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | - | Free Hanging | Free Hanging (In-Line) | - | Copper | Bulk | 2006 | Pan-Lug® | yes | Active | Not Applicable | Crimp, Barrel | - | Gray | - | 15.7mm | Electro-Tin | 4 AWG | Tin | 2 AWG | - | Non-Insulated | Rectangular Tongue | 3/8 Stud | Two Stud Holes | - | 72.39mm | 2.850 72.40mm | 0.620 15.75mm | 0.080 2.03mm | 0.280 (7.11mm) | 0.380 (9.65mm) | - | No | ROHS3 Compliant | ||
| LCD4-38AD-L | ||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. ТипLCAF350-34H-6Anlielectronics Тип | Panduit Corp |
Lug Terminal (6.2/0)AWG 90.7mm 39.1mm Tin
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | - | Free Hanging | Free Hanging (In-Line), 45° Angle | - | Copper | Bulk | 2004 | Pan-Lug® | yes | Obsolete | Not Applicable | Crimp, Barrel | EAR99 | Blue | 8536.90.40.00 | 39.1mm | Electro-Tin | 350MCM (kcmil) | Tin | - | WIRE TERMINAL | Non-Insulated | Rectangular Tongue | 3/4 Stud | Single Stud Hole | - | 90.7mm | - | 1.540 39.12mm | 0.220 5.59mm | 0.840 (21.34mm) | 1.220 (30.99mm) | 0.780 (19.81mm) | No | ROHS3 Compliant | ||
| LCAF350-34H-6 | ||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. ТипLCAF350-78H-6Anlielectronics Тип | Panduit Corp |
Lug Terminal (6.2/0)AWG 97mm 39.1mm Tin
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | - | Free Hanging | Free Hanging (In-Line), 45° Angle | - | Copper | Bulk | 2004 | Pan-Lug® | yes | Obsolete | Not Applicable | Crimp, Barrel | EAR99 | Blue | 8536.90.40.00 | 39.1mm | Electro-Tin | 350MCM (kcmil) | Tin | - | WIRE TERMINAL | Non-Insulated | Rectangular Tongue | 7/8 Stud | Single Stud Hole | - | 97mm | - | 1.540 39.12mm | 0.220 5.59mm | 0.840 (21.34mm) | 1.220 (30.99mm) | 0.910 (23.11mm) | No | ROHS3 Compliant | ||
| LCAF350-78H-6 | ||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. ТипLCDX8-14BF-LAnlielectronics Тип | Panduit Corp |
Lug Terminal 8AWG 44.19mm 12.19mm Electro-Tin
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | - | Free Hanging | Free Hanging (In-Line), Right Angle | - | Copper | Bulk | 2004 | Pan-Lug® | - | Active | Not Applicable | Crimp, Barrel | EAR99 | Red | 8536.90.40.00 | 12.19mm | Electro-Tin | 8 AWG | Tin | 8 AWG | WIRE TERMINAL | Non-Insulated | Rectangular Tongue | 1/4 Stud | Two Stud Holes | - | 44.19mm | - | 0.480 12.19mm | 0.070 1.78mm | 0.180 (4.57mm) | 0.270 (6.86mm) | 0.270 (6.86mm) | No | ROHS3 Compliant | ||
| LCDX8-14BF-L | ||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. ТипLCDX4-14DH-LAnlielectronics Тип | Panduit Corp |
Lug Terminal 4AWG 56.1mm 14mm Tin
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | - | Free Hanging | Free Hanging (In-Line), 45° Angle | - | Copper | Bulk | 2011 | Pan-Lug® | - | Active | Not Applicable | Crimp, Barrel | EAR99 | Gray | 8536.90.40.00 | 14mm | Electro-Tin | 4 AWG | Tin | 4 AWG | WIRE TERMINAL | Non-Insulated | Rectangular Tongue | 1/4 Stud | Two Stud Holes | FEMALE | 56.1mm | - | 0.550 13.97mm | 0.090 2.29mm | 0.280 (7.11mm) | 0.380 (9.65mm) | 0.270 (6.86mm) | No | ROHS3 Compliant | ||
| LCDX4-14DH-L | ||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. ТипLCDX1-56DH-XAnlielectronics Тип | Panduit Corp |
Lug Terminal 1AWG 63.3mm 19.3mm Tin
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | - | Free Hanging | Free Hanging (In-Line), 45° Angle | - | Copper | Bulk | 2004 | Pan-Lug® | - | Active | Not Applicable | Crimp, Barrel | EAR99 | Green | 8536.90.40.00 | 19.3mm | Electro-Tin | 1 AWG | Tin | 1 AWG | WIRE TERMINAL | Non-Insulated | Rectangular Tongue | 5/16 Stud | Two Stud Holes | - | 63.3mm | - | 0.760 19.30mm | 0.120 3.05mm | 0.390 (9.91mm) | 0.520 (13.21mm) | 0.340 (8.64mm) | No | ROHS3 Compliant | ||
| LCDX1-56DH-X | ||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. ТипLCA600-78H-6Anlielectronics Тип | Panduit Corp |
Lug Terminal (8.5/0)AWG 95.5mm 43.2mm Tin
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | - | Free Hanging | Free Hanging (In-Line), 45° Angle | 600 | Copper | Bulk | 2004 | Pan-Lug® | - | Active | Not Applicable | Crimp, Barrel | EAR99 | Green | 8536.90.40.00 | 43.2mm | Electro-Tin | 600MCM (kcmil) | Tin | - | WIRE TERMINAL | Non-Insulated | Rectangular Tongue | 7/8 Stud | Single Stud Hole | FEMALE | 95.5mm | - | 1.700 43.18mm | 0.260 6.60mm | 0.920 (23.37mm) | 1.190 (30.23mm) | 0.910 (23.11mm) | No | ROHS3 Compliant | ||
| LCA600-78H-6 | ||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. ТипLCAF250-58F-XAnlielectronics Тип | Panduit Corp |
Lug Terminal (4.7/0)AWG 64.3mm 32.5mm Tin
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | - | Free Hanging | Free Hanging (In-Line), Right Angle | - | Copper | Bulk | 2004 | Pan-Lug® | - | Obsolete | Not Applicable | Crimp, Barrel | EAR99 | White | 8536.90.40.00 | 32.5mm | Electro-Tin | 250MCM (kcmil) | Tin | - | WIRE TERMINAL | Non-Insulated | Rectangular Tongue | 5/8 Stud | Single Stud Hole | FEMALE | 64.3mm | - | 1.280 32.51mm | 0.170 4.32mm | 0.700 (17.78mm) | 1.020 (25.91mm) | 0.660 (16.76mm) | No | ROHS3 Compliant | ||
| LCAF250-58F-X | ||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. ТипLCAF8-38F-LAnlielectronics Тип | Panduit Corp |
Lug Terminal 8AWG 31.5mm 15.2mm Tin
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | Tin | Free Hanging | Free Hanging (In-Line), Right Angle | - | Copper | Bulk | 2004 | Pan-Lug® | - | Obsolete | Not Applicable | Crimp, Barrel | EAR99 | Red | 8536.90.40.00 | - | Electro-Tin | 8 AWG | - | 8 AWG | WIRE TERMINAL | Non-Insulated | Rectangular Tongue | 3/8 Stud | Single Stud Hole | FEMALE | - | - | 0.600 15.24mm | 0.050 1.27mm | 0.180 (4.57mm) | 0.320 (8.13mm) | 0.410 (10.41mm) | No | ROHS3 Compliant | ||
| LCAF8-38F-L | ||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. ТипLCAX6-10H-LAnlielectronics Тип | Panduit Corp |
Lug Terminal 6AWG 26.9mm 11.4mm Tin
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | - | Free Hanging | Free Hanging (In-Line), 45° Angle | - | Copper | Bulk | 2004 | Pan-Lug® | yes | Active | Not Applicable | Crimp, Barrel | EAR99 | Blue | 8536.90.40.00 | 11.4mm | Electro-Tin | 6 AWG | Tin | 6 AWG | WIRE TERMINAL | Non-Insulated | Rectangular Tongue | 10 Stud | Single Stud Hole | - | 26.9mm | - | 0.450 11.43mm | 0.090 2.29mm | 0.220 (5.59mm) | 0.310 (7.87mm) | 0.200 (5.08mm) | No | ROHS3 Compliant | ||
| LCAX6-10H-L | ||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. ТипLCDX6-10BH-LAnlielectronics Тип | Panduit Corp |
Lug Terminal 6AWG 46mm 11.7mm Tin
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | - | Free Hanging | Free Hanging (In-Line), 45° Angle | - | Copper | Bulk | 2004 | Pan-Lug® | - | Active | Not Applicable | Crimp, Barrel | EAR99 | Blue | 8536.90.40.00 | 11.7mm | Electro-Tin | 6 AWG | Tin | 6 AWG | WIRE TERMINAL | Non-Insulated | Rectangular Tongue | 10 Stud | Two Stud Holes | FEMALE | 46mm | - | 0.460 11.68mm | 0.080 2.03mm | 0.220 (5.59mm) | 0.310 (7.87mm) | 0.200 (5.08mm) | No | ROHS3 Compliant | ||
| LCDX6-10BH-L | ||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. ТипLCDX6-14DH-LAnlielectronics Тип | Panduit Corp |
Lug Terminal 6AWG 54.4mm 12.2mm Tin
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | - | Free Hanging | Free Hanging (In-Line), 45° Angle | - | Copper | Bulk | 2004 | Pan-Lug® | - | Active | Not Applicable | Crimp, Barrel | EAR99 | Blue | 8536.90.40.00 | 12.2mm | Electro-Tin | 6 AWG | Tin | 6 AWG | WIRE TERMINAL | Non-Insulated | Rectangular Tongue | 1/4 Stud | Two Stud Holes | FEMALE | 54.4mm | - | 0.480 12.19mm | 0.080 2.03mm | 0.220 (5.59mm) | 0.310 (7.87mm) | 0.270 (6.86mm) | No | ROHS3 Compliant | ||
| LCDX6-14DH-L | ||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. ТипLCDX1-56DF-XAnlielectronics Тип | Panduit Corp |
Lug Terminal 1AWG 63.8mm 19.3mm Tin
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | - | Free Hanging | Free Hanging (In-Line), Right Angle | - | Copper | Bulk | 2004 | Pan-Lug® | - | Active | Not Applicable | Crimp, Barrel | EAR99 | Green | 8536.90.40.00 | 19.3mm | Electro-Tin | 1 AWG | Tin | 1 AWG | WIRE TERMINAL | Non-Insulated | Rectangular Tongue | 5/16 Stud | Two Stud Holes | - | 63.8mm | - | 0.760 19.30mm | 0.120 3.05mm | 0.390 (9.91mm) | 0.520 (13.21mm) | 0.340 (8.64mm) | No | ROHS3 Compliant | ||
| LCDX1-56DF-X | ||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. ТипLCA6-38H-LAnlielectronics Тип | Panduit Corp |
Lug Terminal 6AWG 40.4mm 15.7mm Tin
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | - | Free Hanging | Free Hanging (In-Line), 45° Angle | - | Copper | Bulk | 2011 | Pan-Lug® | - | Active | Not Applicable | Crimp, Barrel | EAR99 | Blue | 8535.90.80.20 | 15.7mm | Electro-Tin | 6 AWG | Tin | 6 AWG | WIRE TERMINAL | Non-Insulated | Rectangular Tongue | 3/8 Stud | Single Stud Hole | FEMALE | 40.4mm | - | 0.620 15.75mm | 0.060 1.52mm | 0.220 (5.59mm) | 0.310 (7.87mm) | 0.410 (10.41mm) | No | ROHS3 Compliant | ||
| LCA6-38H-L | ||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. ТипLCDX350-12H-6Anlielectronics Тип | Panduit Corp |
Lug Terminal (6.2/0)AWG 117.1mm 39.1mm Tin
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | - | Free Hanging | Free Hanging (In-Line), 45° Angle | - | Copper | Bulk | 2004 | Pan-Lug® | - | Active | Not Applicable | Crimp, Barrel | EAR99 | Blue | 8536.90.40.00 | 39.1mm | Electro-Tin | 350MCM (kcmil) | Tin | - | WIRE TERMINAL | Non-Insulated | Rectangular Tongue | 1/2 Stud | Two Stud Holes | FEMALE | - | - | 1.540 39.12mm | 0.220 5.59mm | 0.840 (21.34mm) | 1.060 (26.92mm) | 0.530 (13.46mm) | No | ROHS3 Compliant | ||
| LCDX350-12H-6 | ||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. ТипLCDX1-12H-XAnlielectronics Тип | Panduit Corp |
Lug Terminal 1AWG 94.7mm 20.3mm Tin
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | - | Free Hanging | Free Hanging (In-Line), 45° Angle | - | Copper | Bulk | 2004 | Pan-Lug® | - | Active | Not Applicable | Crimp, Barrel | EAR99 | Green | 8536.90.40.00 | 20.3mm | Electro-Tin | 1 AWG | Tin | 1 AWG | WIRE TERMINAL | Non-Insulated | Rectangular Tongue | 1/2 Stud | Two Stud Holes | - | 94.7mm | - | 0.800 20.32mm | 0.120 3.05mm | 0.390 (9.91mm) | 0.520 (13.21mm) | 0.530 (13.46mm) | No | ROHS3 Compliant | ||
| LCDX1-12H-X | ||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. ТипLCD300-38DH-XAnlielectronics Тип | Panduit Corp |
Lug Terminal (5.5/0)AWG 85.3mm 29.7mm Tin
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | - | Free Hanging | Free Hanging (In-Line), 45° Angle | - | Copper | Bulk | 2004 | Pan-Lug® | - | Active | Not Applicable | Crimp, Barrel | EAR99 | White | 8536.90.40.00 | 29.7mm | Electro-Tin | 300MCM (kcmil) | Tin | - | WIRE TERMINAL | Non-Insulated | Rectangular Tongue | 3/8 Stud | Two Stud Holes | FEMALE | 85.3mm | - | 1.190 30.23mm | 0.160 4.06mm | 0.650 (16.51mm) | 0.810 (20.57mm) | 0.410 (10.41mm) | No | ROHS3 Compliant | ||
| LCD300-38DH-X | ||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. ТипLCD2-14BF-QAnlielectronics Тип | Panduit Corp |
Lug Terminal 2AWG 50.5mm 15.2mm Tin
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | - | Free Hanging | Free Hanging (In-Line), Right Angle | - | Copper | Bulk | 2004 | Pan-Lug® | - | Active | Not Applicable | Crimp, Barrel | EAR99 | Brown | 8536.90.40.00 | 15.2mm | Electro-Tin | 2 AWG | Tin | 2 AWG | WIRE TERMINAL | Non-Insulated | Rectangular Tongue | 1/4 Stud | Two Stud Holes | FEMALE | 50.5mm | - | 0.600 15.24mm | 0.100 2.54mm | 0.310 (7.87mm) | 0.420 (10.67mm) | 0.270 (6.86mm) | No | ROHS3 Compliant | ||
| LCD2-14BF-Q | ||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. ТипLCAX350-38-6Anlielectronics Тип | Panduit Corp |
Lug Terminal (6.2/0)AWG 74.4mm 39.1mm Tin
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | - | Free Hanging | Free Hanging (In-Line) | - | Copper | Bulk | 2004 | Pan-Lug® | yes | Active | Not Applicable | Crimp, Barrel | EAR99 | Blue | 8536.90.40.00 | 39.1mm | Electro-Tin | 350MCM (kcmil) | Tin | - | WIRE TERMINAL | Non-Insulated | Rectangular Tongue | 3/8 Stud | Single Stud Hole | - | 74.422mm | 2.930 74.42mm | 1.540 39.12mm | 0.220 5.59mm | 0.840 (21.34mm) | 1.060 (26.92mm) | 0.410 (10.41mm) | No | ROHS3 Compliant | ||
| LCAX350-38-6 | ||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. ТипLCMC150-12-XAnlielectronics Тип | Panduit Corp |
CONN TERM RECT RING 150MM #M12
Сборник данных
Сравнение
| Min.:1 Mult.:1 | 4 Weeks | - | Free Hanging | Free Hanging (In-Line) | - | Copper | Bulk | 2013 | LCMC | - | Active | Not Applicable | Crimp, Barrel | EAR99 | - | 8536.90.40.00 | - | Tin | 150mm2 | - | - | - | Non-Insulated | Ring, Tubular | M12 Stud | Two Stud Holes | - | 144.5006mm | 5.689 144.50mm | 1.201 30.51mm | 0.175 4.45mm | 0.650 (16.51mm) | 0.827 (21.01mm) | 0.551 (14.00mm) | - | ROHS3 Compliant | ||
| LCMC150-12-X |
Индекс :
0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ



















