Schneider LMC902CBB10000 technical specifications, attributes, parameters and parts with similar specifications to Silicon Labs SI1084-A-GM.
| Свойство продукта | Значение свойства | |
|---|---|---|
| Классификация | Controllers - Programmable Logic (PLC) | |
| Марка | Schneider | |
| Manufacturer Part Number | CA32A25V12 | |
| Manufacturer | Miscellaneous | |
| Number of HW-interfaces parallel | 0 | |
| Number of digital inputs | 20digital inputs | |
| Number of HW-interfaces industrial Ethernet | 1 | |
| Number of HW-interfaces other | 1 | |
| Number of digital outputs | 16digital outputs | |
| Explosion safety category for gas | None | |
| Number of HW-interfaces RS-485 | 1 | |
| Front built-in possible | No | |
| Appendant operation agent (Ex ib) | No | |
| Number of HW-interfaces RS-232 | 1 | |
| Number of HW-interfaces RS-422 | 1 | |
| Appendant operation agent (Ex ia) | No | |
| Explosion safety category for dust | None | |
| IO link master | No | |
| Model | Compact | |
| Supporting protocol for PROFINET IO | Yes | |
| Supporting protocol for other bus systems | No | |
| Supply voltage DC | 24 - 24 | |
| Type of memory | NVRAM | |
| Supporting protocol for ASI | No | |
| Number of interfaces PROFINET | 0 | |
| Supporting protocol for EtherNet/IP | Yes | |
| Supporting protocol for Data-Highway | No | |
| Supporting protocol for SERCOS | Yes | |
| Number of HW-interfaces Wireless | 0HW-interfaces Wireles | |
| Supporting protocol for INTERBUS-Safety | No | |
| Radio standard Wi-Fi 802.11 | No |
| Свойство продукта | Значение свойства | |
|---|---|---|
| Supporting protocol for DeviceNet | No | |
| Supporting protocol for INTERBUS | No | |
| SIL according to IEC 61508 | None | |
| System accessory | No | |
| Supporting protocol for LON | No | |
| Wall mounting/direct mounting | Yes | |
| Rail mounting possible | No | |
| Supporting protocol for DeviceNet Safety | No | |
| Supporting protocol for PROFINET CBA | Yes | |
| Number of HW-interfaces USB | 1 | |
| Supporting protocol for PROFIsafe | No | |
| Suitable for safety functions | No | |
| Supporting protocol for KNX | No | |
| Supporting protocol for SafetyBUS p | No | |
| Supporting protocol for CAN | Yes | |
| Radio standard UMTS | No | |
| Rack-assembly possible | Yes | |
| Radio standard GSM | No | |
| Supporting protocol for MODBUS | Yes | |
| Supporting protocol for Foundation Fieldbus | No | |
| Supporting protocol for SUCONET | No | |
| Supporting protocol for AS-Interface Safety at Work | No | |
| Supporting protocol for TCP/IP | Yes | |
| Voltage type of supply voltage | DC | |
| Radio standard Bluetooth | No | |
| With optical interface | No | |
| Radio standard GPRS | No | |
| Supporting protocol for PROFIBUS | Yes | |
| Depth | 243 | |
| Height | 310 | |
| Width | 100 |